Honeywell 7600 Scanner User Manual


 
28
Power Save Modes and IR Detection
The 7600 has five programmable power save modes. Refer to the MetroSelect
Programming Guide for additional information on Power Save Modes.
1. Blink Power Save Mode:
Blinks the laser OFF & ON after a programmed period of non-use.
When the scanner recognizes a bar code it will exit the Blink mode.
2. Laser Off Power Save Mode:
Turns the laser OFF after a programmed period of non-use. The motor
continues to spin allowing for a faster “wake” up time.
Any movement detected by the IR will “wake” the scanner from the Laser Off
power save mode (see Figure 28).
3. Laser & Motor Off Power Save Mode:
Turns the laser and motor OFF after a programmed period of non-use.
Any movement detected by the IR will “wake” the scanner from the power
save mode (see Figure 28). This mode’s “wake” time is slightly longer due
to the motor’s need to restart.
4. Dual Action Power Save Mode #1:
“Blinks” the laser OFF & ON after a programmed period of non-use turns the
laser and motor OFF at thirty-minute intervals.
Example:
If the power save
timeout is set to 15
minutes.
Any movement detected by the IR will “wake” the scanner from the power
save mode (see Figure 28).
5. Dual Action Power Save Mode #2 (Default):
Turns the laser OFF after a programmed period of non-use then turns the
motor OFF after thirty-minute intervals.
Example:
If the power save
timeout is set to 15
minutes.
Any movement detected by the IR will “wake” the scanner from the power
save mode (see Figure 28).
Laser starts
“Blinking”
Laser & Motor
turns OFF
Last
Scan
Laser turns
OFF
Motor turns
OFF
Last
Scan