Husky HME-423E Switch User Manual


 
Hardware Installations
2-2
2-2 LED Indicators
There are diagnostic LEDs located on the front panel of HME-421E/423E. They provide primary information
on switch status as described in the table below.
LED Name LED Color LED Function
Green Power is on.
PWR
Off
Power is off or no power is being supplied to the
switch.
Green Power is on.
PWR1
Off
Power is off or no power is being supplied to the
switch.
Green Power is on.
PWR2
Off
Power is off or no power is being supplied to the
switch.
Red
One of the following errors occur:
z Power failure
z UTP port failure
z Fiber port failure
Fault
Off None of the above mentioned errors occurs.
Green This switch unit is the Ring Master.
R.M.
Off This switch unit is NOT the Ring Master.
Green The fiber port is linked.
Blinking
The port is transmitting or receiving packets from a
TX device.
LNK/ACT
Off The fiber port is not linked.
Orange The port is operating in full-duplex mode.
Blinking Orange Collision of packets occurs.
Off
The port is in half-duplex mode or no device is
attached.
Green The port is connected to a network.
Blinking Green
The port is transmitting or receiving packets from a
TX device.
P1-P4
Off The port is not connected to a network.
2-3 RJ-45 Ports
HME-421E/423E has 4 10/100Mbps auto-sensing ports for 10Base-T or 100Base-TX devices connection.
The UTP ports can auto-sense for 10Base-T or 100Base-TX connections. Auto MDI/MDIX function allows
HME-421E/423E to connect to another switch or workstation without changing straight through or crossover
cabling. See Cabling section for straight through and crossover cable schematic.
2-3.1 RJ-45 Pin Assignments
RJ-45 pin assignments as described in the table below:
Pin Number Assignment
1 Tx+
2 Tx-
3 Rx+
6 Rx-