IBM 8485 Server User Manual


 
1. Check the system-board LEDs or the LEDs on the front panel (see
“System-board LEDs” on page 76).
2. Remove the software or device that you added.
3. Run the diagnostic tests to determine whether the server is running correctly.
4. Reinstall the new software or new device.
CD or DVD drive problems
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Symptom Action
The CD or DVD drive is not
recognized.
1. Make sure that:
v The IDE channel to which the CD or DVD drive is attached (primary or
secondary) is enabled in the Configuration/Setup Utility program.
v All cables and jumpers are installed correctly.
v The correct device driver is installed for the CD or DVD drive.
2.
Run the CD or DVD drive diagnostic programs.
3. Reseat the CD or DVD drive cable.
4. Replace the following components one at a time, in the order shown, restarting
the server each time:
a. CD or DVD drive cable
b. CD or DVD drive
c. (Trained service technician only) System board
A CD or DVD is not working
correctly.
1. Clean the CD or DVD.
2. Run the CD or DVD drive diagnostic programs.
3. Reseat the CD or DVD drive cable.
4. Replace the following components one at a time, in the order shown, restarting
the server each time:
a. CD or DVD drive cable
b. CD or DVD drive
The CD or DVD drive tray is not
working.
1. Make sure that the server is turned on.
2. Insert the end of a straightened paper clip into the manual tray-release
opening.
3. Reseat the CD or DVD drive cable.
4. Replace the following components one at a time, in the order shown, restarting
the server each time:
a. CD or DVD drive cable
b. CD or DVD drive
64 xSeries 206m Types 8485 and 8490: Installation Guide