IBM ECS-320A Network Card User Manual


 
SERIAL INTERFACE DEVELOPERS GUIDE
Factory Bit Fields
Adr
Entry Name Mode Initialize 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
104 Lens ID Byte 0x05
Control R/W
105 Reserved Byte 0x00
R/W
106 -Reserved Short 0x0000
110 R/W
112 Operational Short 0x0000
Elapsed R/W
Time (LSBs)
114 Operational Short 0x0000
Elapsed R/W
Time (MSBs)
116 Cal Flash Short 0x0000
Cycle R/W
Count
118 Cal Refresh Short 0x0000
Cycle R/W
Count
120 Over-Temperature Short 0x0000
Alarm R/W
Count
122 Power On / Short 0x0000
Reset Cycle R/W
Count
124- Reserved Short 0x0000
126 R/W
Operational Elapsed Time LSBs
(Minutes)
Operational Elapsed Time MSBs
(Minutes)
Power On / Reset Cycle Count
Over-Temperature Alarm Count
Cal Refresh Cycle Count
Reserved
Cal Flash Cycle Count
Reserved
Lens ID
Res-
er-
ved
Lens
Auto
Det
Reserved
Lens ID Control:
Lens ID 0 – No Lens;
Fixed Focus / No Zoom (IDs 1 through 15):
1 – Reserved; 2 – Reserved; 3 – 13mm; 4 – Reserved; 5 – 25mm; 6 – Reserved;
7 – 50mm; 8 – Reserved; 9 – Reserved; 10 – 100mm; 11 to 15 – Reserved;
Manual Focus / No Zoom (IDs 16 through 31):
16 – Reserved; 19 – 13mm; 20 – Reserved; 21 – 25mm; 22 – Reserved;
23 – 50mm; 24 – Reserved; 25 – Reserved; 26 – 100mm; 27 to 31 – Reserved;
32 to 63 – Reserved for Advanced Lenses
Lens Auto Det 0 – Use Dynamic Configuration Table Lens ID;
1 – Automatically Detect Lens ID Using ADC Channel ANA4 (MS6 Bits)
Nonvolatile Diagnostic Parameters:
Operational Elapsed Time – Incremented Once per Minute
Cal Flash Cycle Count – Incremented Each Time a One-Point, Two-Point or One Point Update NUC
Operation is Performed.
Cal Refresh Cycle Count – Incremented Each Time a One Point Refresh NUC Operation is performed.
Over-Temperature Alarm Count – Incremented Each Time the Camera Internal Temperature Exceeds
55ºC.
Power On/Reset Cycle Count – Incremented Each Time the Camera is Booted.
56