IBM LE-565 Switch User Manual


 
Menu: Diagnosis Heater-specific diagnosis
14
NOTE
This function is not available for BBW 46 S/DBW 46 S.
Note on Air Top 2000
Heating mode is terminated with a short slow-down time, after which the
test functions are available (diagnostic mode). The test starts after a
further acknowledgement by pressing the Enter key or clicking the OK
button. After the component test has been ended by clicking the Cancel
button, the heater will resume normal control mode.
Note on Thermo 50 MAN/trade
The component test is only available when the heater is OFF. The CO
2
adjustment may only be carried out in combustion mode with the heater
in full power.
2.2.5. Line priming
Open the dialog box of the same name using the menu command
Diagnosis/Prime line… or by clicking the button .
Enter the time for priming the line in seconds in the priming time box.
The default is 30 seconds.
Click the <Start priming> button to start the line priming process.
Click the <Stop priming> button to cancel your entry or to stop the line
priming prematurely.
NOTE
The priming process cannot be stopped on some heaters.
2.2.6. To save the data summary
Select menu command Diagnosis/Save summary… to open the report
file dialog box.
The summary shows operating data and control unit information.
Enter as clear a file name as possible in the file name box for the new
text file, e.g. report_dated_011213.
The file extension (.TXT) is added automatically or may be entered
as part of the file name, e.g. Test_011214.txt.
Click the <Save> button to save the summary of the diagnostic data.
2.2.7. To open the data summary
To open an existing summary of diagnostic data, open the report file
dialog box using menu command Diagnosis/Open summary…
Mark the file you want to review by clicking it. The name of the
marked file will be transferred into the file name box.
Click the <Open> button or double click the file name to open the text
file.
The Display summary view will be opened.
Click the <OK> button to close the view.
2.2.8. Start test record
Use the Diagnosis/Start measurement recording… menu command to
open the Protocol file dialog box.
Enter as clear a name as possible into the protocol file name box for
the new text file, e.g. protocol_dated_011213.
The file extension (.TXT) is added automatically or may be entered
as part of the file name, e.g. Test_011214.txt.
Enter the recording interval (the default is 10 seconds).
NOTE
When you have finished the diagnosis, end the measurement recording.
2.2.9. To end measurement recording
The <OK> button starts the recording.
Use the Diagnosis/Measurement recording menu command to end
measurement recording.