Advanced/ZP Technical Product Summary • Page 35
ERROR MESSAGES (CONT.)
FDD Controller Failure The BIOS cannot communicate with the floppy disk drive controller. Check all appropriate connections
after the system is powered down.
HDD Controller Failure The BIOS cannot communicate with the hard disk drive controller. Check all appropriate connections
after the system is powered down.
INTR #1 Error Interrupt channel 1 failed POST.
INTR #2 Error Interrupt channel 2 failed POST.
Invalid Boot Diskette The BIOS can read the disk in floppy drive A:, but cannot boot the system. Use another boot disk.
Keyboard Is Locked...Unlock It The keyboard lock on the system is engaged. The system must be unlocked to continue.
Keyboard Error
There is a timing problem with the keyboard. Set the Keyboard option in Standard CMOS Setup to
Not Installed to skip the keyboard POST routines.
KB/Interface Error There is an error in the keyboard connector.
Off Board Parity Error Parity error in memory installed in an expansion slot. The format is:
OFF BOARD PARITY ERROR ADDR (HEX) = (XXXX)
XXXX is the hex address where the error occurred.
On Board Parity Error Parity is not supported on this product, this error will not occur.
Parity Error ???? Parity error in system memory at an unknown address.
PLUG AND PLAY ERROR MESSAGES
Bad PNP Serial ID Checksum The serial ID checksum of a Plug and Play card was invalid.
Floppy Disk Controller Resource
Conflict
The floppy disk controller has requested a resource that is already in use.
NVRAM Checksum Error, NVRAM
Cleared
The ESCD data was reinitialized because of an NVRAM checksum error. Try rerunning the ICU.
NVRAM Cleared by Jumper The "Clear CMOS" switch has been moved to the ON position and CMOS RAM has been cleared.
NVRAM Data Invalid, NVRAM
Cleared
Invalid entry in the ESCD area.
Parallel Port Resource Conflict The parallel port has requested a resource that is already in use.
PCI Error Log is Full This message is displayed when more than 15 PCI conflict errors are detected. No additional PCI
errors can be logged.
PCI I/O Port Conflict Two devices requested the same resource, resulting in a conflict.
PCI IRQ Conflict Two devices requested the same resource, resulting in a conflict.
Primary Memory Conflict Two devices requested the same resource, resulting in a conflict.
Primary Boot Device Not Found The designated primary boot device (hard disk drive, diskette drive, etc.) could not be found.
Primary IDE Controller Resource
Conflict
The primary IDE controller has requested a resource that is already in use.
Primary Input Device not Found The designated primary input device (keyboard, mouse, or other, if input is redirected) could not be
found.
Secondary IDE Controller Resource
Conflict
The secondary IDE controller has requested a resource that is already in use.
Serial Port 1 Resource Conflict Serial port 1 has requested a resource that is already in use.
Serial Port 2 Resource Conflict Serial port 2 has requested a resource that is already in use.
Static Device Resource Conflict A non-Plug and Play ISA card has requested a resource that is already in use.
System Board Device Resource
Conflict
A non Plug and Play system resource has requested a resource that is already in use.
Table I-3. Plug and Play Error Messages
ISA NMI MESSAGES
ISA NMI Message Explanation
Memory Parity Error at xxxxx Memory failed. If the memory location can be determined, it is displayed as xxxxx. If not, the message
is Memory Parity Error ????.
I/O Card Parity Error at xxxxx An expansion card failed. If the address can be determined, it is displayed as xxxxx. If not, the
message is I/O Card Parity Error ????.
DMA Bus Time-out A device has driven the bus signal for more than 7.8 microseconds.
Table I-4. ISA NMI Messages