Intel® Server Boards S5000PSL and S5000XSL TPS Appendix B: BMC Sensor Tables
Sensor
Name
Sensor
Number
System
Applica-
bility
Sensor Type Event /
Reading
Type
Event Offset
Triggers
Criticality Assert /
De-assert
Readable
Value /
Offsets
Event Data Rearm Standby
Disabled Degraded
IERR Critical
Thermal trip Non-rec
Config error Critical
Presence OK
Proc 2
Status
91h All Processor
07h
Sensor
Specific
6Fh
Disabled Degraded
As and De – Trig Offset M X
Proc 1
Temp
98h All Temperature
01h
Threshold
01h
[u,l] [c,nc] Threshold
defined
As and De Analog R, T A –
Proc 2
Temp
9Ah All Temperature
01h
Threshold
01h
[u,l] [c,nc] Threshold
defined
As and De Analog R, T A –
Bus correctable
error
OK PCIe Link0 A0h Critical
Interrupt
13F
Sensor
Specific
6Fh
PCIe
Link0
Bus
uncorrectable
error
Degraded
As – See the
BIOS EPS
A –
Bus correctable
error
OK PCIe Link1 A1h Critical
Interrupt
13F
Sensor
Specific
6Fh
PCIe
Link1
Bus
uncorrectable
error
Degraded
As – See the
BIOS EPS
A –
Bus correctable
error
OK PCIe Link2 A2h Critical
Interrupt
13F
Sensor
Specific
6Fh
PCIe
Link2
Bus
uncorrectable
error
Degraded
As – See the
BIOS EPS
A –
Bus correctable
error
OK PCIe Link3 A3h Critical
Interrupt
13F
Sensor
Specific
6Fh
PCIe
Link3
Bus
uncorrectable
error
Degraded
As – See the
BIOS EPS
A –
PCIe Link4 A4h Critical
Interrupt
Sensor
Specific
PCIe
Link4
Bus correctable
error
OK As – See the
BIOS EPS
A –
Revision 1.2
Intel order number: D41763-003
103