Intel S5000PSL Computer Hardware User Manual


 
Design and Environmental Specifications Intel® Server Boards S5000PSL and S5000XSL TPS
Revision 1.2
Intel order number: D41763-003
66
5.6 Fan Headers
The server board provides four SSI-compliant 4-pin and four SSI-compliant 6-pin fan headers to
be used as CPU, and IO cooling fans. 3-pin fans are supported on all fan headers. 6-pin fans
are supported on header J3H4, J3H3, J3H2, and J3H1. 4-pin fans are supported on header
J9J1, J5J1, J3H4, J3H3, J9B4, and J9B3. 4-pin fans are not supported on header J3H2, and
J3H1, since these headers are tied to the CPU1 PWM. These fan headers should also not be
used for CPU cooling fans. The pin configuration for each of the 4-pin and 6-pin fan headers is
identical and is defined in the following tables.
Two 4-pin fan headers are designated as processor cooling fans:
- CPU1 fan (J9J1)
- CPU2 fan (J5J1)
Four 6-pin fan headers are designated as hot-swap system fans:
- Hot-swap system fan 1 (J3H4)
- Hot-swap system fan 2 (J3H3)
- Hot-swap system fan 3 (J3H2)
- Hot-swap system fan 4 (J3H1)
Two 4-pin fan headers are designated as rear system fans:
- System fan 5 (J9B4)
- System fan 6 (J9B3)
Table 33. SSI 4-pin Fan Header Pin-out (J9J1, J5J1, J9B3, J9B4)
Pin Signal Name Type Description
1 Ground GND Ground is the power supply ground
2 12V Power Power supply 12 V
3 Fan Tach In FAN_TACH signal is connected to the BMC to monitor the fan speed
4 Fan PWM Out FAN_PWM signal to control fan speed
Table 34. SSI 6-pin Fan Header Pin-out (J3H1, J3H2, J3H3, J3H4)
Pin Signal Name Type Description
1 Ground GND Ground is the power supply ground
2 12V Power Power supply 12 V
3 Fan Tach In FAN_TACH signal is connected to the BMC to monitor the fan speed
4 Fan PWM Out FAN_PWM signal to control fan speed
5 Fan Presence In Indicates the fan is present
6 Fan Fault LED Out Lights the fan fault LED
Note: Intel Corporation server boards support peripheral components and contain a number of
high-density VLSI and power delivery components that need adequate airflow to cool. Intel’s
own chassis are designed and tested to meet the intended thermal requirements of these