Intel SR1550AL Server User Manual


 
Intel
®
Server System SR1550AL/SR1550ALSAS User’s Guide 35
Installing a SAS/SATA Hot-swap Hard Disk Drive
1. Remove the front bezel if it is installed. For instructions, see “Removing and
Installing the Front Bezel”.
2. Open the latch at the front of the hard drive carrier. See letter "A" in the figure
below.
3. Pull out on the black lever and slide the carrier from the server system. See letter
"B" in the figure below.
Figure 29. Removing Hot-swap Disk Carrier from the Server System
4. Remove the hard drive from its wrapper and place it on an antistatic surface.
5. Set any jumpers and/or switches on the drive according to the drive manufacturer's
instructions.
6. With the drive circuit-side down, position the connector end of the drive so that it is
facing the rear of the drive carrier.
7. Align the holes in the drive to the holes in the drive carrier and attach it to the
carrier with the screws that were attached to the plastic retention device.
TP02230
A
B