Intel SR1550AL Server User Manual


 
64 Intel
®
Server System SR1550AL/SR1550ALSAS User’s Guide
Replacing or Adding a Power Supply
Caution: The power supply is only hot-swappable if you have a redundant system with two power
supplies installed. If you only have one power supply installed, before removing or
replacing the power supply, you must first take the server out of service, turn off all
peripheral devices connected to the system, turn off the system by pressing the power
button, and unplug the AC power cord from the system or wall outlet.
The power supply can be replaced if it fails or if one of the fans that is integrated into it
fails. To replace the power supply, use the following instructions.
1. Observe the safety and ESD precautions at the beginning of this book. See “Safety
Information”.
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the server system cover. For instructions, see “Removing the Chassis
Cover”.
4. If a filler panel is installed, use the finger hole to remove the filler panel as shown
in the figure below.
Figure 54. Removing Power Supply Filler Panel from the Server System
5. If a power supply is installed, release the latch (see letter “A”) and remove the
power supply by pulling on the handle (see letter “B”) as shown in the figure below.
TP02242