Intel SR1550ALSAS Server User Manual


 
40 Intel
®
Server System SR1550AL/SR1550ALSAS User’s Guide
Figure 34. Removing the Slimline Optical Drive Assembly from the Server
System
6. If no device will be installed in this location, install a filler blank in this location.
7. Install the server system cover. For instructions, see “Installing the Server System
Cover”.
8. (Optional) Install the front bezel. For instructions, see “Installing the Front Bezel”.
9. Plug all peripheral devices and the AC power cable into the server.
Installing and Removing the PCI Riser Assembly
Removing the PCI Riser Assembly
To remove the PCI riser assembly, use the following instructions.
1. Observe the safety and ESD precautions at the beginning of this book. See “Safety
Information”.
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the server system cover. For instructions, see “Removing the Chassis
Cover”.
4. Remove the processor air duct by lifting straight up.
5. Disconnect any cables attached to any add-in cards.
TP02261
A
B