Intermec SF51 Scanner User Manual


 
Chapter 3 — Troubleshooting and Maintaining the SF51
SF51 Cordless Scanner User’s Guide 25
Problems and Possible Solutions
Problem Possible Solution
Your SF51 has been
misplaced, and you cannot
find it.
If your SF51 is within Bluetooth
communication range of your host
PC, you can send the Bluetooth
Device Page command from EasySet
to locate your SF51. For help, see
“Locating the SF51” on page 28.
You place the SF51 in a
charger and lose Bluetooth
communications.
When you place the SF51 in a 1-bay
or 4-bay charger, you reset the SF51,
and the scanner control firmware
restarts. If you have a Bluetooth
connection, the SF51 disconnects
from the host device while the
firmware resets. For more
information, see “Resetting the
SF51” on page 28.
You cannot establish a
Bluetooth connection (the
blue Intermec Ready-to-
Work indicator is not on).
Scan the following bar code to
reset the scanner to its default
configuration and try establishing
a connection again.
Administrator Reset Factory Defaults
\60\08\55\22
Note: Using the Administrator Reset
Factory Defaults command resets all
settings. As a result, you will lose
Bluetooth communications.