TIME CODE
Playing back the time code
BR-HD50 is also equipped with a time code reader. During playback, the time code or user’s bit data
recorded on the tape is displayed on the monitor or the counter display.
1.Select the time code data to display.
Set the COUNTER switch to “TC” or “UB”.
2.Press the PLAY button to go to the PLAYBACK mode.
J It displays the time code and the user’s bit on the monitor or
the counter display. The counter display mode becomes TCR
or UBR.
Caution on time code playback
z During playback, if a portion of tape without recorded time
code runs through, the time code stops running. Playback con-
tinues.
z If tapes without recorded user’s bit, e.g. those recorded with a
home-use DV VCR, are played back on BR-HD50, “– –” is dis-
played.
COUNTER switch
3DV 2K CH–1/2 S MINP60
W
ARNING 7001
DRUM MOTOR FAILURE
REC INHIBIT
06/10/05 PLAY
11:20:00 TCR 02:00:00:00
Monitor (Status display)
Time code or user’s bit
E-63
EDIT
Using a non-linear editing system
Tape contents of BR-HD50 are captured by a non-linear editing system and the non-linear edited con-
tents are recorded on BR-HD50.
Set the REMOTE/LOCAL switch on the
front panel to REMOTE.
REMOTE [1/2] Menu screen
•Set REMOTE SEL 9-PIN to “ON”.
REMOTE [2/2] Menu screen
z REMOTE FF/REW MODE:
Use this item to select the operation to be per-
formed if the FF or REW command is received
during playback. (FF/REW or Search)
If the search operation is not performed prop-
erly, set it to “SEARCH”.
z CONTROLLER TYPE (in the REMOTE [2/2]
Menu screen):
Set this item to “TYPE1”.
Set the INPUT SELECT switch located
on the front panel to HDV/DV.
Set the IEEE1394 switch located on
the front panel to match the video for-
mat.
•Set to DV position for DV mode, and to
HDV position for HDV mode.
Set the REMOTE/LOCAL switch on the
front panel to the position matching
the REMOTE menu below.
REMOTE [1/2] Menu screen
Set REM SEL HDV/DV to ON or LOC+REM.
Set this item to ON if it is to become
enabled only when the REMOTE/LOCAL
switch on the front panel is set to REMOTE.
Set this item to LOC+REM if it is to become
enabled regardless of the position of the
REMOTE/LOCAL switch.
Memo
z If the time code of BR-HD50 is not displayed correctly when the non-linear side moves one frame
forward or backward, set the STL/F.ADV: DV in the SYSTEM [1/2] Menu screen to “FRAME.” (In DV
mode only)
z When controlling with RS-422A using the HDV format, only the capture operation is supported.
Connection
Analog video
IEEE1394 terminal
VIDEO OUT
AUDIO OUT
RS-422A
REMOTE
Analog audio
Non-linear system
IEEE1394 (image, audio, control)
Control with RS-422A
(Analog signals)
Setting
Control with the IEEE1394 ter-
minal (Digital signals)
Setting