JVC DLA-HD10KSU/E Projector User Manual


 
35
Replacing the Lamp
The life of light-source lamps used for this unit is about 2000 hours.
The lamp life of 2000 hours is merely the average life span of light-source lamps and we do not provide any guarantee for
this figure.
The lamp life may not reach 2000 hours depending on the operating conditions.
Deterioration progresses rapidly when the remaining lamp usage time is short. Get ready or replace with a new lamp (lamp
unit) when the accumulated usage time exceeds 1900 hours. Depending on the operating conditions, the lamp may have to
be exchanged earlier. If the image is dark or color tone abnormal, replace the lamp as soon as possible.
You can also check the accumulated hours of usage. Please refer to ALamp TimeB of the AInformationB menu.
(A Pages 28, 32)
Setting APower SaveB of the AOptionsB menu to AOnB does not affect the usage time of the light-source lamp.
(A Pages 28, 32)
Please consult your authorized dealer when purchasing a new lamp unit.
oReplacement Lamp (Lamp Unit) Part No.: BHL5008-S
oWhen the lamp usage time exceeds 1900 hours
(but less than 2000 hours)
The [LAMP] indicator lights up and the [TEMP] indicator
starts blinking upon turning on the power (standby
mode).
The ALamp replacementB message will be displayed on
the screen when projection starts.
The message can be cleared by pressing any button on
the remote control or this unit.
oWhen the lamp usage time exceeds 2000 hours
(but less than 2010 hours)
The [LAMP] indicator lights up and the [FAN] indicator
starts blinking upon turning on the power (standby
mode).
When the lamp usage time exceeds 2000 hours during
projection, the ALamp replacementB message will be
displayed on the screen when projection starts and the
AWarningB mark will appear blinking.
Press the [EXIT] button to clear the display. However,
the same AWarningB and ALamp replacementB
messages will be displayed after 1 hour.
When the unit is switched to the standby mode or turned
off after the lamp usage time exceeds 2000 hours, it
cannot be switched back to the projection mode again.
In this case, replace with a new lamp (lamp unit) and
reset the lamp time (A Page 38).
oWhen the lamp usage time reaches 2010 hours
The unit quits the projection mode (operating mode)
and switches into the cool down mode.
The [LAMP] indicator will light up and the [TEMP] and
[FAN] indicators will appear blinking.
The projection mode (operating mode) cannot be
restored until a new lamp (lamp unit) is replaced and the
lamp time reset.
Light-source Lamp and Lamp Usage Time
About Lamp Replacement
If this unit is installed in a constricted place, attempting to replace the lamp in that place may cause injury. Move this unit
to a place large enough to perform work.
Use only genuine replacement parts for the lamp unit. Otherwise, malfunction may occur. Also, never attempt to re-use
an old lamp unit. This may cause marked performance deterioration or lamp blowout, thus leading to unit malfunction.
Broken pieces of the lamp outside this unit may also cause injuries during lamp unit exchange.
Do not replace the lamp immediately after this unit has been used. The temperature of the lamp is still high and this may
cause a burn. Allow a cooling period of 1 hour or more before replacement.
Before replacing the lamp unit, pull out the power plug from the outlet while the [STAND BY] indicator is still on.
Replacing a lamp with the plug connected to the outlet may cause injuries or electric shocks.
ENGLISH
DLA-HD10_EN-FR.book Page 35 Thursday, November 10, 2005 12:54 PM