The horizontal placement must result in the patch pattern crossing the
scanner’s sensor locations. Refer to the following illustration.
Patch code bar dimensions and optical properties should conform to
the Kodak specifications outlined in Kodak Publication, A-61599.
Patch codes must be printed parallel to the document lead edge.
KEY:
A — the minimum distance from the document edge to the start of the patch
code = 0.25 in.
B — the maximum distance from the document edge to the end of the patch
code = 1.70 in.
C — the recommended minimum width of the patch code centered around the
sensor location = 1.0 in.
D — the distance from the transport/feeder center to the patch code sensor =
2.0 in.
— center line of the scanner document feeder with the side guides
centered.
— allowable vertical region for the printed patch code.
The entire region above the patch code must be free of printing.
A
C
C
B
DD
Patch sensors