Kodak 9500 All in One Printer User Manual


 
A-61124 March 1999 6-5
BX/Y/Z — Scan resolution
The BX/Y/Z command defines scanning resolution for the current
mode.
Data Field Command Field
res B X/Y/Z
Data Field Description Value(s)
res scan resolution in dots per inch 70 to 300*
* Values must be specified in increments of 10 dpi. If not, values will be
rounded to the nearest 10 dpi by the scanner.
NOTE: Leading zeros are not permitted.
CX — Clear buffers
The CX command resets the image buffer and initializes the
Sequential ID Number to 1. This command is intended for use
only during integration testing and should not be used in a
production scanning application.
IMPORTANT: Executing the CX command may cause images in
the buffer to be lost. Similarly, if the command is
executed while there are documents in the
transport, the new images may also be lost.
Data Field Command Field
none C X
DC — Sequential ID
initiator
The DC command is used to set the Sequential ID Number
(document count).
Data Field Command Field
cnt level D C
Data Field Description Value(s)
cnt image number value 0–999999999
level 9
The following example shows how the DC command could be
used:
The host application wants the starting image Sequential ID
Number (document count) to be 101.
The Sequential ID Initiator command must enter a value one less
than the desired starting value (to start with 101, the cnt value
must be 100).
HEX31303039 4443
CHAR 1 0 0 9 D C