Kodak 9500 All in One Printer User Manual


 
6-16 A-61124 March 1999
The following table illustrates how the use of a string of scanner-
unique commands can temporarily override current mode
parameters:
RESULT
ACTION Compression Resolution
Scanner is in Mode 1 3* 200*
Host executes SCSI Send command
with 2FX300BX
2 300
Host executes SCSI Send command
with 4HA
3* 200*
Host executes SCSI Send command
with 1HA
3* 200*
*Parameter default value.
Permanently changing individual parameters
A permanent change to an individual parameter is performed by
temporarily overriding a single parameter and then sending a
scanner-unique Define Mode (JA) command to save the values to
a specified mode.**
The following table illustrates how the use of a scanner-unique JA
command can be used to permanently change a current mode
parameter:
RESULT
ACTION Compression Resolution
Scanner is in Mode 1 3* 200*
Host executes SCSI Send command
with 2FX
2 200*
Host executes SCSI Send command
with 4JA
Host executes SCSI Send command
with 4HA
2 300
Host executes SCSI Send command
with 1HA
3* 200*
* Parameter default value.
** The value(s) may be saved to the current mode or any of the
other modes.