Kodak 9500 All in One Printer User Manual


 
A-61124 March 1999 6-11
KX/Y/Z — Scan contrast
The KX/Y/Z command defines the contrast used for the current
mode.
NOTE: A contrast of 0 results in a fixed threshold.
Data Field Command Field
cont K X/Y/Z
Data Field Description Value(s)
cont scan contrast ranging from 0 (fixed
thresholding) to 100 (fully adaptive)
0–100
NOTES:
Leading zeros are not permitted.
If multi-level screening is enabled (LX/Y/Z 0), this command is
used to enable/disable Error Diffusion.
LX/Y/Z — Dither pattern
(screen)
The LX/Y/Z command selects one of the eight screens for the
current mode.
Data Field Command Field
screen L X/Y/Z
Data Field Description Value(s)
screen 2-level screen (no screen)
16-level screen
32-level screen
64-level screen
3-level screen
4-level Bayer Dither
16-level Bayer Dither
64-level Bayer Dither
0
1
2
3
4
5
6
7
NOTE: Level is defined as the levels of gray simulated by the
screen.
MC — Count Only mode
The MC command enables or disables Count Only operation. The
image address does not change and no images are stored when
using Count Only mode.
Data Field Command Field
stat M C
Data Field Description Value(s)
stat disables Count Only mode 0
enables Count Only mode 1