A-61500 April 2009 5-9
Cleaning the background strips
18.Using the green tabs pull off the upper and lower background strips
and set them aside.
19.Vacuum the areas where the background strips are adhered to.
20.Reinstall the upper and lower background strips.
Cleaning the imaging guides
21.Turn the screw on each end of the upper imaging guide, remove it
from its position and set it aside
IMPORTANT:Allow 5 minutes for lamps to cool.
22.Turn the screw on each end of the lower imaging guide, remove it
from its position and set it aside.
Lower strip
Upper strip
Lower imaging guide