Lantronix EDS32PR Server User Manual


 
9: Line and Tunnel Settings
EDS User Guide 65
5. Click Submit.
6. Repeat above steps as desired, according to additional tunnel(s) available on your product.
Flush Serial Data Select Enabled to flush the serial data buffer on a new connection.
Block Serial Data
Select On to block, or not tunnel, serial data transmitted to the
device.
Block Network
Select On to block, or not tunnel, network data transmitted to the
device.
Password Enter a password that clients must send to the device within 30 seconds from
opening a network connection to enable data transmission.
The password can have up to 31 characters and must contain only alphanumeric
characters and punctuation. When set, the password sent to the device must be
terminated with one of the following: (a) 0x0A (LF), (b) 0x00, (c) 0x0D 0x0A (CR
LF), or (d) 0x0D 0x00.
Email on Connect Select whether the device sends an email when a connection is made. Select
None if you do not want to send an email. Otherwise, select the Email profile to
use for sending.
Email on Disconnect Select whether the device sends an email when a connection is closed. Select
None if you do not want to send an email. Otherwise, select the Email profile to
use for sending.
Tunnel - Accept Mode
Settings (continued)
Description