Lantronix UDS10 Network Card User Manual


 
UDS10/UDS100 User Guide Configuring the UDS Using Telnet or the Serial Port
35
Disconnect Time (Inactivity Timeout)
Use Disconnect Time to set an inactivity timeout. The unit drops the connection if
there is no activity on the serial line before the set time expires. Enter time in the
following format: mm:ss, where m is the number of minutes and s is the number of
seconds. To disable the inactivity timeout, enter 00:00. Range is 0 (disabled) to 5999
seconds (99 minutes, 59 seconds). The default is 0.
Send Characters
Enter up to two characters in hexadecimal representation for the SendChar settings.
If the unit receives a character on the serial line that matches one of these
characters, it sends the character immediately, along with any awaiting characters, to
the TCP connection. This action minimizes the response time for specific protocol
characters on the serial line (for example, ETX, EOT). Setting the first SendChar to
00 disables the recognition of the characters. Alternatively, the unit can interpret two
characters as a sequence (see Pack Control on page 34).
Telnet Terminal Type
This parameter displays only if the terminal type option is enabled in Disconnect
Mode. If this option is enabled, use the terminal name for the Telnet terminal type.
Enter only one name.
If the terminal type option is enabled, the unit also reacts to the EOR (end of record)
and binary options that can be used for applications like terminal emulation to IBM
hosts.
Channel (Port) Password
This parameter displays only if the channel (port) password option is enabled in
Disconnect Mode. If the option is enabled, set a password on the serial port.
Expert Settings
Note: Change these settings using Telnet or serial connections only, not
Web Manager.
Caution: Only an expert should change these parameters. These
changes have serious consequences.
Figure 5-7. Expert Settings Options