Lenovo 3658 Computer Hardware User Manual


 
Diagnostic error codes
Refer to the following diagnostic error codes when using the diagnostic tests. See "Running tests" on
page 35 for the specic type for information about the Diagnostic programs.
In the following index, X can represent any number.
Diagnostic Error Code FRU/Action
000-000-XXX BIOS Test Passed
No action
000-002-XXX BIOS Timeout 1. Flash the system. See "Flash update procedures"
on page 467
2. System board
000-024-XXX BIOS Addressing test failure 1. Flash the system. See "Flash update procedures"
on page 467
2. System board
000-025-XXX BIOS Checksum Value error 1. Flash the system. See "Flash update procedures"
on page 467
2. System board
000-026-XXX FLASH data error 1. Flash the system. See "Flash update procedures"
on page 467
2. System board
000-027-XXX BIOS Conguration/Setup error 1. Run Setup
2. Flash the system. See "Flash update procedures" on
page 467
3. System board
000-034-XXX BIOS Buffer Allocation failure
1. Reboot the system
2. Flash the system. See "Flash update procedures" on
page 467
3. Run memory test
4. System board
000-035-XXX BIOS Reset Condition detected 1. Flash the system. See "Flash update procedures"
on page 467
2. System board
000-036-XXX BIOS Register error 1. Flash the system. See "Flash update procedures"
on page 467
2. System board
000-038-XXX BIOS Extension failure 1. Flash the system. See "Flash update procedures"
on page 467
2. PCI adapter card
3. System board
000-039-XXX BIOS DMI data error 1. Flash the system. See "Flash update procedures"
on page 467
2. System board
000-195-XXX BIOS Test aborted by user
Information only Re-start the test, if necessary
000-196-XXX BIOS test halt, error threshold exceeded
1. Press F3 to review the log le
2. Re-start the test to reset the log le
44 ThinkCentre Hardware Maintenance Manual