Diagnostic Error Code FRU/Action
014-197-XXX Parallel port test warning 1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility" on page 39
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
014-198-XXX Parallel port test aborted 1. If a component is called out, make sure it is
connected and/or enabled
2. Flash the system and re-test. See "Flash update
procedures" on page 467
3. Go to "Undetermined problems" on page 65
014-199-XXX Parallel port test failed, cause unknown
1. Go to "Undetermined problems" on page 65
2. Flash the system and re-test. See "Flash update
procedures" on page 467
3. Replace component under function test
014-2XX-XXX 014-3XX-XXX Parallel port failure
1. External parallel device
2. System board
015-000-XXX USB port Interface Test Passed
No action
015-001-XXX USB port Presence 1. Remove USB device(s) and re-test
2. System board
015-002-XXX USB port Timeout 1. Remove USB device(s) and re-test
2. System board
015-015-XXX USB port External Loopback failure 1. Remove USB device(s) and re-test
2. System board
015-027-XXX USB port Conguration/Setup error 1. Flash the system. See "Flash update procedures"
on page 467
2. System board
015-032-XXX USB port Device Controller failure System board
015-034-XXX USB port buffer allocation failure
1. Reboot the system
2. Flash the system and re-test. See "Flash update
procedures" on page 467
3. Run memory test
4. System board
015-035-XXX USB port Reset condition detected 1. Remove USB device(s) and re-test
2. System board
015-036-XXX USB port Register error System board
015-040-XXX USB port IRQ failure
1. Run setup and check for conicts
2. Flash the system. See "Flash update procedures" on
page 467
3. System board
015-195-XXX USB port Test aborted by user
Information only Re-start the test, if necessary
Chapter 7 Symptom-to-FRU Index 51