Lenovo 7090 Computer Hardware User Manual


 
Diagnostic Error Code FRU/Action
018-250-XXX PCI Card Services error 1. PCI card
2. Riser card, if installed
3. System board
020-000-XXX PCI Interface Test Passed
No action
020-0XX-XXX PCI Interface error 1. PCI card
2. Riser card, if installed
3. System board
020-195-XXX PCI Test aborted by user
Information only Re-start the test, if necessary
020-196-XXX PCI test halt, error threshold exceeded
1. Press F3 to review the log le
2. Re-start the test to reset the log le
020-197-XXX PCI test warning
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility" on page 39
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
020-198-XXX PCI test aborted
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility" on page 39
2. Flash the system and re-test. See "Flash update
procedures" on page 467
3. Go to "Undetermined problems" on page 65
020-199-XXX PCI test failed, cause unknown 1. Go to "Undetermined problems" on page 65
2. Flash the system and re-test. See "Flash update
procedures" on page 467
3. Replace component under function test
020-262-XXXPCI system error 1. PCI card
2. Riser card, if installed
3. System board
025-000-XXXIDE interface Test Passed
No action
025-00X-XXX 025-01X-XXX IDE interface failure
1. IDE signal cable
2. Check power supply voltages
3. Reseat IDE signal cable
4. IDE device
5. System board
025-027-XXX IDE interface Conguration/Setup error
1. IDE signal cable
2. Flash the system. See "Flash update procedures" on
page 467
3. Reseat IDE signal cable
4. IDE device
5. System board
Chapter 7 Symptom-to-FRU Index 53