Lenovo 7090 Computer Hardware User Manual


 
Diagnostic Error Code FRU/Action
030-196-XXX SCSI interface test halt, error threshold
exceeded
1. Press F3 to review the log le
2. Re-start the test to reset the log le
030-197-XXX SCSI interface test warning
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility" on page 39
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
030-198-XXX SCSI interface test aborted
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility" on page 39
2. Flash the system and re-test. See "Flash update
procedures" on page 467
3. Go to "Undetermined problems" on page 65
030-199-XXX SCSI interface test failed, cause unknown 1. Go to "Undetermined problems" on page 65
2. Flash the system and re-test. See "Flash update
procedures" on page 467
3. Replace component under function test
035-000-XXX RAID interface Test Passed
No action
035-0XX-XXX RAID interface Failure
1. RAID signal cable
2. RAID device
3. RAID adapter card, if installed
4. System board
035-195-XXX RAID interface Test aborted by user Information only Re-start the test, if necessary
035-196-XXX RAID interface test halt, error threshold
exceeded
1. Press F3 to review the log le
2. Re-start the test to reset the log le
035-197-XXX RAID interface test warning
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility" on page 39
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
035-198-XXX RAID interface test aborted
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility" on page 39
2. Flash the system and re-test. See "Flash update
procedures" on page 467
3. Go to "Undetermined problems" on page 65
035-199-XXX RAID interface test failed, cause unknown
1. See "Undetermined problems" on page 65
2. Flash the system and re-test. See "Flash update
procedures" on page 467
3. Replace component under function test
071-000-XXX Audio port Interface Test Passed
No action
Chapter 7 Symptom-to-FRU Index 55