Diagnostic Error Code FRU/Action
071-00X-XXX 071-01X-XXX 071-02X-XXXAudio port
error
1. Run Setup
2. Flash the system. See "Flash update procedures" on
page 467
3. System board
071-03X-XXX Audio port failure
1. Speakers
2. Microphone
3. Audio card, if installed
4. System board
071-04X-XXX Audio port failure
1. Run Setup
2. Audio card, if installed
3. System board
071-195-XXX Audio port Test aborted by user
Information only Re-start the test, if necessary
071-196-XXX Audio port test halt, error threshold
exceeded
1. Press F3 to review the log le
2. Re-start the test to reset the log le
071-197-XXX Audio port test warning 1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility" on page 39
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
071-198-XXX Audio port test aborted 1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility" on page 39
2. Flash the system and re-test. See "Flash update
procedures" on page 467
3. Go to "Undetermined problems" on page 65
071-199-XXX Audio port test failed, cause unknown
1. See "Undetermined problems" on page 65
2. Flash the system and re-test. See "Flash update
procedures" on page 467
3. Replace component under function test
071-25X-XXX Audio port failure
1. Speakers
2. Audio card, if installed
3. System board
080-000-XXX Game Port interface Test Passed
No action
080-XXX-XXX Game Port interface Error
1. Remove the game port device and re-test the
system
080-195-XXX Game Port interface Test aborted by user
Information only Re-start the test, if necessary
080-196-XXX Game Port interface test halt, error
threshold exceeded
1. Press F3 to review the log le
2. Re-start the test to reset the log le
56 ThinkCentre Hardware Maintenance Manual