Lenovo 7090 Computer Hardware User Manual


 
Diagnostic Error Code FRU/Action
025-02X-XXX 025-03X-XXX 025-04X-XXX IDE Interface
failure
1. IDE signal cable
2. Check power supply
3. Reseat IDE signal cable
4. IDE device
5. System board
025-195-XXX IDE interface Test aborted by user Information only Re-start the test, if necessary
025-196-XXX IDE interface test halt, error threshold
exceeded
1. Press F3 to review the log le
2. Re-start the test to reset the log le
025-197-XXX IDE interface test warning
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility" on page 39
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
025-198-XXX IDE interface test aborted
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility" on page 39
2. Flash the system and re-test. See "Flash update
procedures" on page 467
3. Go to "Undetermined problems" on page 65
025-199-XXX IDE interface test failed, cause unknown
1. Go to "Undetermined problems" on page 65
2. Flash the system and re-test. See "Flash update
procedures" on page 467
3. Replace component under function test
030-000-XXX SCSI interface Test Passed
No action
030-00X-XXX 030-01X-XXX SCSI interface failure 1. SCSI signal cable
2. Check power supply
3. SCSI device
4. SCSI adapter card, if installed
5. System board
030-027-XXX SCSI interface Conguration/Setup error 1. SCSI signal cable
2. Flash the system. See "Flash update procedures" on
page 467
3. SCSI device
4. SCSI adapter card, if installed
5. System board
030-03X-XXX 030-04X-XXX SCSI interface error 1. SCSI signal cable
2. Check power supply
3. SCSI device
4. SCSI adapter card, if installed
5. System board
030-195-XXX SCSI interface Test aborted by user
Information only Re-start the test, if necessary
54 ThinkCentre Hardware Maintenance Manual