LOREX Technology DHU500 SERIES Network Card User Manual


 
30 INSTALLERS MANUAL | Copyright © 2006 Digimerge Technologies Inc.
Recording Set
SECTION 4
Motion Recording
Setup and configurations for Motion Sensor events.
1. CH1-CH4 FRAMERATE: Set the number of Frames Per Second. Press the
K and L buttons
to highlight, and press the SEL button to select, and use the
I and J and SEL buttons to
change the settings.
2. QUALITY - Set the quality level for the recording to High, Mid or Low
3. POST MOTION DURATION: Set the duration that the DVR will record once motion is detected:
5, 30, 60, 90, 120, 150, 180, 210 or 240 seconds.
4. SETUP MOTION: Configuration for each Motion Sensor enabled Camera Press the
K and L
buttons to highlight the Setup Motion option, and press the SEL button to access the SETUP
MOTION submenu. Press the K and L buttons to highlight a specific Camera, and press the
SEL button to select.
• POST MOTION: Set the length of time to continue recording after motion has stopped.
AREA: Press the SEL button on the AREA option to specify segments of the Camera view
to have Motion Detection. Use the
KLIJ buttons to navigate around the Motion Setup
screen, and press the SEL button to turn a segment ON/OFF. Press the MENU button once
complete. Dark Blue indicates that a section has been selected for motion detection, and
blank areas indicate that motion will not be detected in those areas.
SENSE: Sets the Sensitivity of the Motion Detection: Use the
I and J and SEL buttons
to change the setting to High, Mid, Low or Off.
5. SAVE & EXIT: Saves any changes made, and exits to the Main Menu. Press the
K and L buttons
to highlight, and press the SEL button to accept the changes.
CH1 Frame Rate:
CH2 Frame Rate:
CH3 Frame Rate:
CH4 Frame Rate:
CH1 Recording Quality
CH1 Recording Quality
CH1 Recording Quality
CH1 Recording Quality
Post Alarm Duration
Setup Motion
Save & Exit
15 FPS
15 FPS
15 FPS
15 FPS
HIGH
HIGH
MED
LOW
150 SEC
Post Motion(5~240sec)
Set CH1 Motion Area
Set CH1 Motion Area
Set CH1 Motion Area
Set CH1 Motion Area
CH1 Motion Sensitivity:
CH1 Motion Sensitivity:
CH1 Motion Sensitivity:
CH1 Motion Sensitivity:
Save & Exit
150 SEC
HIGH
HIGH
MED
LOW