Lucent Technologies 9076 Network Router User Manual


 
Log Messages
Message descriptions
SP Switch Router Adapter Guide - 1.4 Update 2 October 22, 1999 B-11
“RX-TBIC transientt error(s) detected IER1=0x%x, IER2=0x%x”,
LOG_FILE: /var/log/gr.console
SOURCE_FILE: rx/tbsi_svc.c
SCOPE: CARD
CONTEXT: RUNNING
SEVERITY: INFO
DESCRIPTION: This message is logged when a TBIC transient error occurs.
“Rx timed-out, src_node=%d, msg_id=%d,
bytes rxed: %d, bufnum: %d, bufaddr: 0x%x.”
LOG_FILE: /var/log/gr.console
SOURCE_FILE: rx/tbsi_rx.c
SCOPE: CARD
CONTEXT: RUNNING
SEVERITY: INFO
DESCRIPTION: This message is logged when the RX CPU has detected a packet receive
timed-out condition. A packet receive timed-out condition is expected. However, if the
condition occurs frequently, it might be a signal that something is not working / configured
correctly.
“SEND TOD service message received "
LOG_FILE: /var/log/gr.console
SOURCE_FILE: tx/tbsi_svc.c
SCOPE: CARD
CONTEXT: RUNNING
SEVERITY: INFO
DESCRIPTION: This message is logged when the TX-CPU receives a SEND TOD
service message from the RX-CPU. This message indicates that a SEND TOD service
message is being sent to the adjacent switch chip.
“Sending Grid Init”
“Sending IF Init for IF 0x%x.”
LOG_FILE: /var/log/gr.console
SOURCE_FILE: rx/tbsi_ipc.c
SCOPE: CARD
CONTEXT: RUNNING
SEVERITY: INFO
DESCRIPTION: This message is logged when the SP Switch Router Adapter card is
loaded, configured, and is requesting the RMS to create and bring up the interface for the
card.
“Sending IF RESET message to TX-CPU.”
LOG_FILE: /var/log/gr.console
SOURCE_FILE: rx/tbsi_svc.c
SCOPE: CARD
CONTEXT: RUNNING
SEVERITY: INFO