Lynx L-210 Network Router User Manual


 
15
Figure 8 (Static IP Connection Setup)
To complete the connection you must now click the apply button. The apply button will temporarily
save this connection. To make the change permanent you need to click on Save Settings (at the
side of the page). At the system commands page, click on Save All.
4.4.1.6 Classical IP over ATM (CLIP, defined in RFC1577) Connection Setup
The Classical IP over ATM (CLIP) support provides the ability to transmit IP packets over an ATM
network, CLIP support will encapsulate IP in an AAL5 packet data unit (PDU) frame using
RFC1577and it utilizes an ATM aware version of the ARP protocol (ATMARP. support only allows
for PVC support; it does not support SVC).
To configure the Lynx L-210 for a CLIP connection, click on Setup and then click on New
Connection. The default CLIP connection setup is displayed. At the Type field select CLIP and the
CLIP connection setup page is displayed; figure 9 illustrates a typical CLIP configuration. Give your
CLIP connection a unique name; the name must not have spaces and cannot begin with numbers.
In this case the unique name is called CLIP1. Select the VPI and VCI settings; your DSL service
provider or your ISP will supply these; in this case the DSL service provider is using 0,101. Also
select the quality of service (QOS); leave the default value if you are unsure or the ISP did not
provide this information. You can also enable Network Address Translation (NAT) and the Firewall
options. If you are unsure, leave these in the default mode.