Impulse DataLogger Series 3 Instruction Manual 2/1/05
9 of 16
The Alarm History provides the data for reviewing recorded alarms and information
on each alarm occurrence.
-ALARM HISTORY -
Alm: 1 OF 26
Run: 1369
Upper Limit1 Err
01/16/04 15:14
01/28/04 08:44:13
Date & Time:
Used to time stamp all
history and trace data.
Alarm number
Run where Alarm
occured
Alarm Description
Date and time of Alarm
-ALARM HISTORY -
U1-01: 000.00 Hz
U1-02: 000.00 Hz
U1-03: 000.00 A
U1-04: 0000
01/28/04 08:44:13
-ALARM HISTORY -
U1-05: 000.00 Hz
U1-06: 000.0 VAC
U1-07: 000 VDC
U1-08: 000.0 Hp
01/28/04 08:44:13
-ALARM HISTORY -
U1-09: 000.0 %Torque
U1-10: 00000000
U1-11: 00000000
U1-12: 00000000
01/28/04 08:44:13
-ALARM HISTORY -
U1-13: 0000 H
01/28/04 08:44:13
U1-01 = Frequency Reference
U1-02 = Output Frequency
U1-03 = Output Amps
U1-04 = Control Method
U1-05 = Motor speed
U1-06 = Motor Voltage
U1-07 = DC bus voltage
U1-08 = Output Hp
U1-09 = % Torque Output
U1-10 = Input terminal status
U1-11 = Output terminal status
U1-12 = Operation status
U1-13 = Run timer (hours)