March Products 120 III (PC620) Personal Computer User Manual


 
User Manual version 2503
LIBRA 120 III (PC620 Intel 815E)
6-123
G-1-4: OVER VOLTAGE PROTECTION
u +5VDC output: +5.7VDC output min. +6.5VDC output max.
u +12VDC output: +13.3VDC output min. +15.6VDC output max.
u +3.3VDC output: +3.7VDC output min. +4.5VDC output max.
G-1-5: SHORT CIRCUIT PROTECTION
Output short circuit is defined to be a short circuit load of 0.1
ohm. In the event of short circuit condition on +3.3V, +5V or
+12V, the power supply will shutdown and latch off. The
power supply shall return to normal operation after the short
circuit has been removed and the power switch has been
turned off for no more than 2 seconds.
In the event of short circuit condition on 12V, the power
supply will not latch off. The power supply shall return to
normal operation as soon as the short circuit has been
removed and the power switch has been turned off for no
more than 2 seconds.
G-1-6: AC INPUT LINE REQUIREMENT
Parameter Min. Nom. Max. Unit
VIN (115VAC) 90 115 135 VAC rms
VIN (230VAC) 180 230 263 VAC rms
VIN Frequency 47 - 63 Hz
u Input current: 4.0A @115V
AC
, 2.0A @230V
AC
u Inrush current: 50A @115V
AC
, 80A @230V
AC
u Efficiency: >68% min. @full load, 115V
AC
& 230V
AC
PDF created with pdfFactory trial version www.pdffactory.com