Mocomtech CIM-550 Modem User Manual


 
CiM-550 IP Enabled Satellite Modem Rev. 2
CiM IP Module Checkout & Fault Isolation CD/CIM550.IOM
422
14.2.5 MAIN MENU
Figure 14-1. Main Menu
To use this onterface, select the appropriate sub-menu or the entry by pressing the
character indicated at the right. Enter x to return to the previous menu.
14.2.6 RESTORING FACTORY DEFAULT CONFIGURATION
The following sections in this guide assume that the CiM is still in factory default
configuration for IP. If that’s not the case, the factory default configuration can be
restored from the menu:
Step Procedure
1
From the Main Menu, select Administration sub-menu.
2
From the Administration menu, select Operations and Maintenance sub-menu.
3
From the Operations and Maintenance menu, select Database Operations sub-menu
4
From the Database Operations menu, select Restore Factory Default option
5
Confirm when prompted.
This will erase any user configuration and restore the CiM to factory default
configuration.
14.2.7 CIM 1 CONFIGURATION
CiM has 2 data interfaces - a LAN interface and a WAN interface. The LAN interface is
a 10/100baseT Ethernet port (fei0). The WAN interface is the serial synchronous HDLC
interface (hdl0). The Ethernet MAC address is factory assigned and cannot be changed.
14.2.1.1 SETTING IP ADDRESS(ES)
Step Procedure
1
From the Main Menu select Interface Configuration sub-menu.
2
From the Interface Configuration Menu select Ethernet Interface (fei0)
3
Set IP Address to 172.16.10.10
4
Set Subnet Prefix Length to 24
5
From the Interface Configuration Menu select Satellite/HDLC Interface (hdl0).
6
Set IP Address to 10.1.1.1
7
Set Subnet Prefix Length to 24
8
Set RX – Enable/Disable and TX – Enable/Disable to Enable.
9
From Receive HDLC Channel Address menu set HDLC Addr 1 to 1 (0x0001)
The other parameters can be left to their factory default settings.