Mocomtech CIM-550 Modem User Manual


 
CiM-550 IP Enabled Satellite Modem Rev. 2
Front Panel Menus CD/CIM550.IOM
39
4.1.5.2.5 SELECT\CONFIG\REMCONT
DISPLAY SELECTIONS/DESCRIPTION
SELECT REMOTE CONTROL:
LOCAL REMOTE (PRESS ENT)
LOCAL
REMOTE
If LOCAL is selected then remote control will be
disabled. Remote monitoring is still possible.
If REMOTE is selected AND If the unit has not been
defined as an EDMAC SLAVE then the following
sub-menu will be displayed:
SELECT\CONFIG\REMCONT\REMOTE
DISPLAY SELECTIONS/DESCRIPTION
REMOTE CONTROL: BAUDRATE
INTERFACE (PRESS ENTER)
BAUDRATE
INTERFACE
EDIT LOCAL BUS BAUDRATE:
19200 BAUD FORMAT 8-N-1
BAUDRATE screen
Edit the baud rate of the remote control bus,
connected locally to the M&C computer.
Selections are 300, 1200, 2400, 4800, 9600
and 19200 baud are possible.
FORMAT selectionas are: 8-N-1, 7-E-2, 7-O-
2.
The asynchronous character format is FIXED
at 8 data bits, 1 stop bit, no parity (8-N-1).
SELECT. INTERFACE: EIA-232
EIA485-2W EIA485-4W (ENT)
INTERFACE screen
EIA232
EIA485-2W
EIA485-4W
At this point the user will be further prompted
to enter the bus address.
IN EIA-232 MODE THE BUS
ADDRESS IS FIXED AT 0000
In EIA-232 mode the bus address is
fixed at 0, and this screen is
displayed.
EDIT UNIT'S BUS ADDRESS:
0245 (PRESS ENTER)
If either RS485 mode is selected, this
screen is displayed.
The valid range of addresses is from
1 to 9999.