Mocomtech CIM-550 Modem User Manual


 
CiM-550 IP Enabled Satellite Modem Rev. 2
Remote Control CD/CIM550.IOM
63
Parameter
Type
Command
(Instruction
Code and
qualifier)
Arguments for
Command or
Response to
Query
Description of arguments
(note that all arguments are ASCII numeric
codes, that is, ASCII codes between 48 and 57)
Response to Command
(target to controller)
Query
(Instruction
Code and
qualifier)
Response to
query
(target to
controller)
1 = Tx Spectrum Inverted
All other codes invalid.
Example:TSI=0 (which is normal)
TSI* (message ok, but not
permitted in current mode)
argument)
Tx
Scrambler
TSC= 1 byte, value of
0 or 1
Command or Query.
Tx Scrambler state, where:
0 = Off
1 = On (V.35 in transparent mode, synchronous in
framed mode
All other codes invalid.
Example: TSC=1 (which is scrambler On)
TSC= (message ok)
TSC? (received ok,
but invalid argument found)
TSQ* (message ok, but not
permitted in current mode)
TSC? TSCS=x
(same format as
command
argument)
Tx Power
Level
TPL= 4 bytes Command or Query.
Tx Output power level between 0 and -20 dBm
(minus sign assumed). Example: TPL=13.4 (which
is
-13.4 dBm)
TPL= (message ok)
TPL? (received ok,
but invalid arguments
found)
TPL* (message ok, but not
permitted in current mode)
TPL?
TPL=xx.x
(same format as
command
arguments)
Tx Clock
Source
TCK=
1 byte, value of
1,2 or 3
Command or Query.
Tx Clock source, where:
1 = Internal
2 = External
3 = Loop timed (use Rx satellite clock)
All other codes invalid.
Example: TCK=2 (which is External Clock)
TCK= (message ok)
TCK? (received ok,
but invalid argument found)
TCK* (message ok, but not
permitted in current mode)
TCK?
TCK=x
(same format as
command
argument)
Tx Carrier
On/Off State
TXO=
1 byte, value of
0, 1 or 2
Command or Query.
Tx Carrier On/Off state, where:
0 = Off due to front panel or rem. control command
1 = On
TXO= (message ok)
TXO? (received ok,
but invalid argument found)
TXO* (message ok, but not
per
mitted in current mode)
TXO? TXO=x
(Note that 2 is
not a valid
argument when
used as a