Mocomtech SLM-5650 Modem User Manual


 
SLM-5650 Satellite Modem Revision 1
Remote Control MN/SLM5650.IOM
B–21
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Rx BERT
Reset
BRS= None Command only.
Reset Rx BERT
Example: BRS=
BRS=
BRS?
BRS*
BRS#
N/A N/A
Rx BERT
Errors
N/A 7 bytes Query only.
Read the total number of Bit Errors.
Example: ERR=9999999
N/A ERR? N/A
Rx BERT
BER
N/A 6 bytes Query only.
Unit returns the value of the BERT BER in the form a.b x 10
-c
. First
three bytes are the value. Last two bytes are the exponent. Returns
0.0E00 if the BERT is not synchronized to a pattern.
Example: BBR=4.9E12
N/A BBR? BBR=a.bEcc
(see description of
arguments)
BERT Pattern PAT= 1 byte, value
of 0 thru 8
Command or Query.
BERT Pattern, where:
0=2047
1=Mark
2=Space
3=1:1
4=1:3
5=2^15-1
6=2^20-1
7=2^23-1
8=MIL-188
Example: PAT=0 (2047 Pattern)
PAT=
PAT?
PAT*
PAT#
PAT? PAT=x
(see description of
arguments)
Insert Tx
BERT Error
BEI= None Command only.
Insert single bit error in Tx BERT
Example: BEI=
BEI=
BEI?
BEI*
BEI#
N/A N/A
Circuit ID
String
CID= 24 bytes Command or Query.
Sets or queries the user-defined Circuit ID string, which is a fixed
length of 24 characters.
Valid characters include:
Space ( ) * + – , . / 0 9 and A thru Z
CID=
CID?
CID*
CID#
CID? CID=x
(see description of
arguments)