Mocomtech SLM-5650 Modem User Manual


 
SLM-5650 Satellite Modem Revision 1
Remote Control MN/SLM5650.IOM
B–34
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
AUPC
Minimum
Power Level
AMN= 5 bytes Command or Query.
Minimum Tx Output power level, where:
s=sign ( + / - )
xx.x = Tx Output power level, +10.0 and –40.0 dBm.
Example: AMN=-13.4
AMN=
AMN?
AMN*
AMN#
AMN? AMN=sxx.x
(see description of
arguments)
AUPC Eb/N0
Target Set
Point
AET= 4 bytes Command or Query.
AUPC Eb/N0 Target, where:
xx.x = AUPC Eb/N0 Target, 3.2 to 16.0 dB.
Example: AET=13.4
AET=
AET?
AET*
AET#
AET? AET=xx.x
(see description of
arguments)
AUPC
Maximum
Tracking Rate
AMT= 3 bytes Command or Query.
AUPC Maximum Tracking Rate, where:
x.x = Maximum Tracking Rate, 0.5 to 6.0 dBm/minute in
increments of .5.
Example: AMT=0.5
AMT=
AMT?
AMT*
AMT#
AMT? AMT=x.x
(see description of
arguments)
AUPC Local
Carrier Loss
Action
LCL= 1 byte, values
of 0 thru 2
Command or Query.
Tx Output Power level setting when local carrier is lost, where:
0=Hold current output power level
1=Goto Nominal output power level
2=Goto Maximum output power level
Example: LCL=0
LCL=
LCL?
LCL*
LCL#
LCL? LCL=x
(see description of
arguments)
AUPC Remote
Carrier Loss
Action
RCL= 1 byte, values
of 0 thru 2
Command or Query.
Tx Output Power level setting when remote carrier is lost, where:
0=Hold current output power level
1=Goto Nominal output power level
2=Goto Maximum output power level
Example: RCL=0
RCL=
RCL?
RCL*
RCL#
RCL? RCL=x
(see description of