Moxa Technologies EDS-408A Switch User Manual


 
EDS-408A/405A Series User’s Manual Featured Functions
3-41
Email Address
Setting Description Factory Default
Max. 30
Characters
You can set up to 4 email addresses to
receive warning emails from EDS.
None
Send Test Email
After finishing with the email settings, you should first press the Activate button to activate those
settings, and then press the Send Test Email button to verify that the settings are correct.
NOTE
Auto warning e-mail messages will be sent through an authentication protected SMTP server that
supports the CRAM-MD5, LOGIN, and PAIN methods of SASL (Simple Authentication and
Security Layer) authentication mechanism.
We strongly recommend not entering your Account Name and Account Password if auto warning
e-mail messages can be delivered without authentication mechanism.
Configuring Relay Warning
The Auto Relay Warning function uses relay output to alert the user when certain user-configured
events take place. There are two basic steps required to set up the Relay Warning function:
1. Configuring Relay Event Types
Select the desired Event types from the Console or Web Browser Event type page (a
description of each event type is given later in the Relay Warning Events setting subsection).
2. Activate your settings
After configuring, you will need to activate your MOXA EtherDevice Switch’s Relay Event
Types.
Relay Warning Events Settings
NOTE: The user interface for EDS-408A shows 8 ports.