Power
Input Voltage 12 to 45 VDC, redundant inputs
Input Current (@24V) Max. 0.26A: (EDS-408A/405A)
Max. 0.43A: (EDS-408A/405A-MM-SC,
EDS-408A/405A-SS-SC,
EDS-408A/405A-MM-ST)
Connection One removable 6-pin terminal block
Overload Current Protection Present
Reverse Polarity Protection Present
Mechanical
Dimensions
53.6 × 135 × 105 mm (W × H × D)
Weight 0.65 kg
Installation DIN-Rail, Wall Mounting (optional kit)
Casing IP30 protection, metal case
Environment
Operating Temperature 0 to 60°C (32 to 140°F)
-40 to 75°C (-40 to 167°F) for -T models
Storage Temperature -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity 5% to 95% (non-condensing)
Regulatory Approvals
Safety UL60950 (E212360), UL 508, CSA C22.2 No. 60950,
EN60950 (pending)
EMI FCC Part 15, CISPR (EN55022) class A
EMS EN61000-4-2 (ESD), Level 3
EN61000-4-3 (RS), Level 3
EN61000-4-4 (EFT), Level 3
EN61000-4-5 (Surge), Level 3
EN61000-4-6 (CS), Level 3
Shock IEC60068-2-27
Freefall IEC60068-2-32
Vibration IEC60068-2-6
WARRANTY 5 years