ISI5634PCI/4/8 User Guide
I11 Display diagnostic information for the last modem con-
nection, such as DSP and firmware version, link type,
line speed, serial speed, type of error correction/data
compression, number of past retrains, etc.
Command: Nn Modulation Handshake
Values: n = 0 or 1
Default: 1
Description: N0 Modem performs handshake only at communication
standard specified by S37 and the B command.
N1 Modem begins handshake at communication standard
specified by S37 and the B command. During hand-
shake, fallback to a lower speed can occur.
Command: On Return Online to Data Mode
Values: 0, 1, 3
Default: None
Description: O0 Exit online command mode and return to data mode (see
+++AT<cr> escape sequence ).
O1 Issue a retrain and return to online data mode.
O3 Issue a rate renegotiation and return to data mode.
Command: P Pulse Dialing
Values: P, T
Default: T
Description: Configures the modem for pulse (non-touch-tone)
dialing. Dialed digits are pulsed until a T command or
dial modifier is received.
Command: Qn Result Codes Enable/Disable
Values: n = 0 or 1
Default: 0
Description: Q0 Enable result codes.
Q1 Disable result codes.
Q2 Returns an OK for backward compatibility with some
software.