Command: Xn Result Code Selection
Values: n = 07
Default: 4
Description: X0 Basic result codes (e.g., CONNECT); does not look for
dial tone or busy signal.
X1 Extended result codes (e.g., CONNECT 46000 V42bis);
does not look for dial tone or busy signal.
X2 Extended result codes with NO DIALTONE; does not
look for busy signal.
X3 Extended result codes with BUSY; does not look for dial
tone.
X4 Extended result codes with NO DIALTONE and BUSY.
X5 Extended result codes with NO DIALTONE and BUSY.
X6 Extended result codes with NO DIALTONE and BUSY.
X7 Basic result codes with NO DIALTONE and BUSY.
Command: Yn Long Space Disconnect
Values: n = 0
Default: 0
Description: Y0 Disable sending or responding to long space break
signal on disconnect.
Y1 Enable sending or responding to long space break sig-
nal on disconnect. (Not supported.)
Command: Zn Modem Reset
Values: n = 0 or 1
Default: None
Description: Z0 Resets modem to profile saved by last &W command.
Z1 Same as Z0.
Command: &Bn V.32 Auto Retrain
Values: n = 1
Default: 1
Description: &B0 Disable V.32 auto retrain. (Not supported.)
&B1 Enable V.32 auto retrain.