ISI5634PCI/4/8 User Guide
Command: \Nn Error Correction Mode Selection
Values: n = 05, or 7
Default: 3
Description: \N0 Non-error correction mode with data buffering (buffer
mode; same as &Q6).
\N1 Direct mode.
\N2 MNP reliable mode. If the modem cannot make an MNP
connection, it disconnects.
\N3 V.42/MNP auto-reliable mode. The modem attempts first
to connect in V.42 error correction mode, then in MNP
mode, and finally in non-error-correction (buffer) mode
with continued operation.
\N4 V.42 reliable mode. If the modem cannot make a V.42
connection, it disconnects.
\N5 V.42, MNP, or non-error correction (same as \N3).
\N7 V.42, MNP, or non-error correction (same as \N3).
Command: \Qn Flow Control Selection
Values: n = 0, 1, or 3
Default: 3
Description: \Q0 Disable flow control (same as &K0).
\Q1 XON/XOFF software flow control (same as &K4).
\Q2 CTS-only flow control. Not supported.
\Q3 RTS/CTS hardware flow control (same as &K3).
Command: \Tn Inactivity Timer
Values: n = 0, 1255
Default: 0
Description: \Tn Sets the time (in minutes) after the last character is sent
or received that the modem waits before disconnecting.
A value of zero disables the timer. Applies only in
buffer mode.
Note: You can also set the inactivity timer by chang-
ing the value of S30.
Command: \Vn Protocol Result Code
Values: n = 0, 1, or 2
Default: 1