A - 4
TM
APP. A
STAR
CODES (HEX/CONTROL) : 11 / <DC1> or 11 n / <DC1> n
FUNCTION : Set select mode
DETAIL DESCRIPTION :
1. When using serial interface printer
This function differs depending on the setting of DIP switch 4.
a) When the DC1, DC3 invalid mode is set DIP switches 4-1 to 4-4 are all set
to ON), the printer ignores this code.
b) In the DC1, DC3 valid mode (with DIP switches 4-1 to 4-4 set to OFF),
when the printer receives a <DC1> code, the deselect mode is canceled and
data following this code is input to buffer.
c) If the printer receives a <DC1> n code (n is the DIP switch controlled
address) during the addressable mode (with DIP switches 4-1 to 4-4 set to
other settings than a) and b) above), the deselect mode is canceled and data
following this code is input to the buffer.
Note that addressable mode is valid only when optional RS-422A interface
is installed.
2. When using parallel interface printer
When the printer receives a <DC1> code, the deselect mode is canceled and
data following this code is input to the buffer.
CODES (HEX/CONTROL) : 12 / <DC2>
FUNCTION : Cancel inverted print mode
APPLICATION LIMIT : This code is valid only when input at the
beginning of a line.
DETAIL DESCRIPTION : Cancel the inverted character mode.