Mustek PP3000 Printer User Manual


 
A - 11
TM
APP. A
STAR
CODES (HEX/CONTROL) : 1B 36 / <ESC> 6
FUNCTION : Select IBM character set #2
APPLICATION LIMIT : This code is only valid when the character
code table set by DIP switches 2-7 and 2-8 is IBM character set #1 or #2.
DETAIL DESCRIPTION : Selects IBM character set #2.
CODES (HEX/CONTROL) : 1B 37 / <ESC> 7
FUNCTION : Select IBM character set #1
APPLICATION LIMIT : This code is only valid when the character
code table set by DIP switches 2-7 and 2-8 is IBM character set #1 or #2.
DETAIL DESCRIPTION : Selects IBM character set #1.
CODES (HEX/CONTROL) : 1B 3A / <ESC> :
FUNCTION : Select 8 CPI character size
APPLICATION LIMIT : This code is valid only when received at the
beginning of a line.
DETAIL DESCRIPTION : 8 CPI character size is selected. The
maximum number of print columns is set by DIP switch (paper width setting) 2-
5 as follows:
DIP sw 2-5 ON OFF
Paper width setting (inch) 3.25/3.0 2.25
Maximum no. of print columns 22 15
CODES (HEX/CONTROL) : 1B 40 / <ESC> @
FUNCTION : Initialize printer
DETAIL DESCRIPTION : Cancels the various conditions set after the
power was turned on and resets the printer to the initial settings in effect when
the power is turned on. In this instance, contents of the line buffer and the data
buffer are not cleared, and the peripheral unit drive pulse width are not changed.