NEC 5800/320Lc Server User Manual


 
Windows Setup and Operation 3-49
Evaluate Start and Stop of CPU Modules
This section describes how to confirm the continuous system operation after stopping one of the
CPU modules.
1.
Confirm that the CPU modules are duplicated.
To check if the CPU modules are duplicated, see the status LEDs of the CPU modules.
[Indications status LEDs when CPU modules are duplicated]
LED
CPU module#1
(Operating)
CPU module#2
(Operating)
1 CPU module status LED1 - -
2 CPU module status LED2 Green Green
2.
Use the ft server utility to stop the operation of a CPU module to remove.
From [Start], select [All Programs], [NEC ESMPRO Agent] then [ft server utility] to start the
ft server utility. Then, from the ft server utility, select [CPU Module] then the CPU module to
stop from the [FTSever] tree on the left pane, and click [Down] of [Bring Up/Bring Down].