NEC 5800/320Lc Server User Manual


 
Troubleshooting 7-17
On-screen error message Cause Action
0B71 System temperature out
of Range
Ambient temperature is out
of range.
Fan is faulty.
CPU/PCI module board is
faulty.
Check the setting in SETUP
Clean the fan.
Replace the fan.
Replace the CPU/PCI
module board.
0B80 BMC Memory Test Failed
0B81 BMC Firmware Code
Area CRC check failed
0B82 BMC core Hardware
failure
0B83 BMC IBF or OBF check
failed
0B90 BMC Platform
Information Area
corrupted
0B91 BMC update firmware
corrupted
BMC is faulty.
Replace the PCI module
board.
0B92 Internal Use Area of
BMC FRU corrupted
SROM is faulty.
BMC is faulty.
Replace the back panel
board.
Replace the PCI module
board.
0B93 BMC SDR Repository
empty
0B94 IPMB signal lines do not
respond
0B95 BMC FRU device failure
0B96 BMC SDR Repository
failure
0B97 BMC SEL device failure
BMC is faulty.
Replace the PCI module
board.
0B98 BMC SEL Overflow
SEL (System Event Log)
overflowed.
Erase the unnecessary SEL.
0BB0 SMBIOS - SROM data
read error
0BB1 SMBIOS - SROM data
checksum bad
SROM is faulty.
Back panel board is faulty.
Replace the back panel board.
0BD0 1st SMBus device
address not
acknowledged
0BD1 1st SMBus device Error
detected
0BD2 1st SMBus timeout
PCI module board #1 is faulty.
0BD3 2nd SMBus device
address not
acknowledged
0BD4 2nd SMBus device Error
detected
0BD5 2nd SMBus timeout
CPU module board #1 is faulty.
Check cable connection.
Replace the board.