NEC 5800/320Lc Server User Manual


 
7-14 Troubleshooting
POST Error Messages
Powering on the server automatically starts the self-diagnostic program, POST (Power On
Self-Test). When POST detects any error, it displays an error message and its measure on the
display unit. Follow the table below to troubleshoot such errors.
Phoenix BIOS 4.0 Release 6.0.XXXX
:
CPU=Pentium III XXX MHz
0640K System RAM Passed
0127M Extended RAM Passed
WARNING:
02B0: Diskette drive A error.
:
press <F1> to resume, <F2> to SETUP
Message indicating a floppy disk drive erro
r
TIPS: For error messages on optional PCI board, refer to the manual provided with those options.
On-screen error message Cause Action
0200 Failure Fixed Disk
Configuration error in Setup
menu.
Hard disk is faulty.
CPU module board is faulty.
PCI module board is faulty.
Check configuration in Setup
menu.
Replace the hard disk.
Replace the CPU module
board.
Replace the PCI module
board.
0210 Stuck Key Keyboard connection error
Disconnect the keyboard
and connect it back again.
Replace the keyboard.
Replace the PCI module
board.
0211 Keyboard error Keyboard is faulty.
0212 Keyboard Controller
Failed
Keyboard controller is faulty.
Check the keyboard
connection.
Restart the server.
Replace the PCI module
board.
0213 Keyboard locked -
Unlock key switch
Keyboard is locked. Unlock the key switch.
0220 Monitor type does not
match CMOS - Run
SETUP
Illegal monitor type is
specified.
Select "Get Default Value"
from the Setup menu.
Clear the CMOS data.
0230 System RAM Failed at
offset
DIMM is faulty.
Replace DIMM.
Replace the CPU module
board.
0231 Shadow RAM Failed at
offset
DIMM is faulty.
Replace DIMM.
Replace the CPU module
board.