NETGEAR 7000 Series Managed Switch Administration Guide
Getting Started 1-3
v1.1, May 2006
config network parms ipaddress netmask gateway
6. To enable these changes to be retained during a reset of the switch, type Ctrl-Z to return to the
main prompt, type save config at the main menu prompt, and type y to confirm the changes.
7. To view the changes and verify in-band information, issue the command: show network.
8. The switch is configured for in-band connectivity and ready for Web-based management.
Configuring for Out-Of-Band Connectivity
To monitor and configure the switch using out-of-band connectivity, use the console port to
connect the switch to a terminal desktop system running terminal emulation software. The console
port connector is a male DB-9 connector, implemented as a data terminal equipment (DTE)
connector.
The following hardware is required to use the console port:
• VT100-compatible terminal, or a desktop, or a portable system with a serial port running
VT100 terminal emulation software.
• An RS-232 crossover cable with a female DB-9 connector for the console port and the
appropriate connector for the terminal.
Perform the following tasks to connect a terminal to the switch console port using out-of-band
connectivity:
1. Connect an RS-232 crossover cable to the terminal running VT100 terminal emulation
software.
2. Configure the terminal emulation software as follows:
a. Select the appropriate serial port (serial port 1 or serial port 2) to connect to the console.
b. Set the data rate to 115,200 baud.
c. Set the data format to 8 data bits, 1 stop bit, and no parity.
d. Set the flow control to none.
IP Address Unique IP address for the switch. Each IP parameter is made up of four
decimal numbers, ranging from 0 to 255. The default for all IP parameters is
zeroes (0.0.0.0).
Subnet Subnet mask for the LAN.
gateway IP address of the default router, if the switch is a node outside the IP range of
the LAN.