Niles Audio 8 Switch User Manual


 
33
Event 2 - TV Auto Turn Off
If the TV is on when the “System Off” key is pressed, this step turns it off.
Event 3 - Auto Volume Reset
The volume of the Preamp may be automatically lowered to minimum, then raised to any
level you choose.
Note: This feature requires that the preamp’s “Volume Up/Down” commands be taught to
their respective Function Key addresses on the “Default” page of memory using IntelliFile
II software. You can customize this feature to the Preamp you are using by determining
the duration of the “Volume Down” command (issued to bring the Preamp’s volume to
absolute minimum), and then the duration of the “Volume Up” command (issued to bring
the Preamp’s volume up to whatever level you decide is appropriate).
Event 4 - Preamp Auto Turn Off
If the Preamp is on when the “System Off” key is pressed, this step turns it off.
Event 5 - Component Auto Turn Off
All components which show sync when the “System Off” key is pressed are turned off.
Event 6 - “System Off” Ending Sequence
An “Ending Sequence” of up to 26 steps may be issued to reconfigure any peripheral
devices to their default positions after the system is powered down.
Note: The IR commands used to power off all of the components in the system are
automatically issued from the “Preamp”, “TV”, and “Component” power memory
addresses on their respective “Tabs” as programmed via IntelliFile II.
3H. The Audio, Video, and Assignable Relays with Control Voltage
Output
The IntelliControl enables you to control devices that are triggered or operated via 12v DC
control voltages or normally-open / normally-closed dry contact closures. There are three
relay groups: Audio, Video, and Assignable. More than one device or more than one
function can be triggered (turned on) by the same relay group, if desired.
Relay Voltage Limitations
There is a 300mA limit to the combined output of all of the 12V DC control outputs. Add up
the combined draw for all devices triggered by the Audio, Video, and Assignable control
voltage outputs. If the total combination is within the limit, it is acceptable to trigger more
than one device from any one control output.