Nokia 12 GSM MODULE REMOTE I/O Network Card User Manual


 
8. COMMAND SYNTAX
The command syntax of control messages varies according to the activated
options. There may also be spaces in aliases defined for commands as seen in
the example below. However, only one space character is accepted between
words. The message identifier and password are case sensitive.
Note: A control message always begins with a message identifier. Otherwise the
message is not interpreted as a Remote I/O control message, and is stored in the
SIM card or the Nokia 12 GSM Module memory.
Control message without a password:
<message identifier> <command / alias>
term123 Output_Set All On
Control message without a password with an alias defined:
<message identifier> <command / alias> <parameter>
term123 Output_Pulse All On 1h30m
Control message with a password:
<message identifier> <password> <command / alias>
term123 password Output_Set All On
Control message with a password with an alias defined:
<message identifier> <password> <command / alias>
<parameter>
term123 password Output_Pulse All On 1h30m
26/49